世界牙科技术
0
首页 > 网上书店 > 2022年8月第七期口腔种植专刊
日期:2022/07/30
前往购买本期杂志,或者关注微信公众号:
idpc1997
日本患者应用6mm短种植体的临床、影像学和患者满意度的回顾性研究与两年随访

前往购买本期杂志,或者关注微信公众号:
idpc1997

参考文献

1. Solar P, Aro G, Ulm C, Bernhart T. The ef-fects of tooth loss on the anatomy of the maxilla [in French]. Schweiz Monatsschr Zahnmed 1998;108:871–878. 

2. Vinter I, Krmpotic´-Nemanic´ J, Hat J, Jalsovec D. Does the alveolar process of the maxilla always disappear after tooth loss? [in German] Laryngorhinootologie 1993;72:605–607. 

3. Esposito M, Pellegrino G, Pistilli R, Felice P. Rehabilitation of posterior atrophic edentulous jaws: Prostheses supported by 5 mm short implants or by longer implants in augmented bone? One-year results from a pilot randomised clinical trial. Eur J Oral Implantol 2011;4:21–30.

4. Feldman S, Boitel N, Weng D, Kohles SS, Stach RM. Five-year survival dis-tributions of short-length (10 mm or less) machined-surfaced and Osseotite implants. Clin Implant Dent Relat Res 2004;6:16–23.

5. Renouard F, Nisand D. Impact of implant length and diameter on survival rates. Clin Oral Implants Res 2006;17:35–51.

6. Srinivasan M, Vazquez L, Rieder P,  Moraguez O, Bernard JP, Belser UC. Survival rates of short (6 mm) micro-rough surface implants: A review of literature and meta-analysis. Clin Oral Implants Res 2014;25:539–545.

7. Thoma DS, Haas R, Tutak M, Garcia A, Schincaglia GP, Hämmerle CH. Random-ized controlled multicentre study com-paring short dental implants (6 mm) ver-sus longer dental implants (11–15 mm) in combination with sinus floor elevation procedures. Part 1: Demographics and patient-reported outcomes at 1 year of loading. J Clin Periodontol 2015;42: 72–80.

8. Friberg B. The posterior maxilla: Clini-cal considerations and current concepts using Brånemark system implants. Peri-odontol 2000 2008;47:67–78.

9. Friberg B, Ekestubbe A, Sennerby L. Clinical outcome of Brånemark system implants of various diameters: A retro-spective study. Int J Oral Maxillofac Im-plants 2002;17:671–677.

10. Renouard F, Nisand D. Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study. Clin Implant Dent Relat Res 2005;7(suppl):s104–s110.

11. Toia M, Galli S, Cecchinato D,  Wennerberg A, Jimbo R. Clinical evi-dence of OsseoSpeed EV implants: A retrospective study and characteriza-tion of the newly introduced system. Int J Periodontics Restorative Dent 2019;39:863–874.

12. Pommer B. Use of the Oral Health Im-pact Proἀle (OHIP) in clinical oral im-plant research. J Dent Oral Craniofac Epidemiol 2013;1:3–10. 

13. Okada S, Koretake K, Miyamoto Y, Oue H, Akagawa Y. Risk factor for dental im-plant failure under appropriate plaque control. PLoS One 2013;30;8:e63992.

14. Pierrisnard L, Renouard F, Renault P, Barquins M. Influence of implant length and bicortical anchorage on implant stress distribution. Clin Implant Dent Relat Res 2003;5:254–262.

15. Goené R, Bianchesi C, Hüerzeler M, et al. Performance of short implants in partial restorations: 3-year follow-up of Osseotite implants. Implant Dent 2005;14:274–280.

16. Harder S, Dimaczek B, Açil Y, Terheyden H, Freitag-Wolf S, Kern M. Molecular leakage at implant-abutment connec-tion-in vitro investigation of tightness of internal conical implant-abutment con-nections against endotoxin penetration. Clin Oral Investig 2010;14:427–432. 

17. Zipprich H, Weigl P, Ratka C, Lange B, Lauer HC. The micromechanical behav-ior of implant-abutment connections under a dynamic load protocol. Clin Im-plant Dent Relat Res 2018;20:814–823.

18. Brunski JB. Biomechanical factors af-fecting the bone-dental implant inter-face. Clin Mater 1992;10:153–201.

19. Bornstein M, Lussi A, Schmid B, Belser UC, Buser D. Early loading of nonsub-merged titanium implants with a sand-blasted and acid-etched (SLA) surface: 3-year results of a prospective study in partially edentulous patients. Int J Oral Maxillofac Implants 2003;18:659–666.

20. Buser D, Mericske-Stern R, Dula K, Lang NP. Clinical experience with one-stage, non-submerged dental implants. Adv Dent Res 1999;13:153–161.

21. Pan YH, Lin HK, Lin JC, et al. Evaluation of the peri-implant bone level around platform-switched dental implants: A retrospective 3-year radiographic study. Int J Environ Res Public Health 2019;16:2570.

22. Chrcanovic BR, Albrektsson T,  Wennerberg A. Platform switch and dental implants: A meta-analysis. J Dent 2015;43:629–646.

23. Friberg B, Sennerby L, Gröndahl K, Bergström C, Bäck T, Lekholm U. On cutting torque measurements during implant placement: A 3-year clinical pro-spective study. Clin Implant Dent Relat Res 1999;1:75–83.

24. Stocchero M, Toia M, Cecchinato D, Becktor JP, Coelho PG, Jimbo R. Biome-chanical, biologic, and clinical outcomes of undersized implant surgical prepa-ration: A systematic review. Int J Oral Maxillofac Implants 2016;31:1247–1263.

25. Juodzbalys G, Kubilius M. Clinical and radiological classiἀcation of the jaw-bone anatomy in endosseous dental implant treatment. J Oral Maxillofac Res 2013;4:e2.

26. Cha JY, Pereira MD, Smith AA, et al. Multiscale analyses of the bone-implant interface. J Dent Res 2015;94:482–490.

27. Arabi SR, Shishehian A, Khazaei S, et al. Effect of dental implantation on the hard and soft tissues around the ad-jacent natural teeth. Dent Med Probl 2019;56:331–336.

28. Al Amri MD. Influence of interimplant distance on the crestal bone height around dntal implants: A systematic re-view and meta-analysis. J Prosthet Dent 2016;115:278–282.

29. Klokkevold PR, Han TJ. How do smoking, diabetes, and periodonti-tis affect outcomes of implant treat-ment? Int J Oral Maxillofac Implants 2007;22(suppl):s173–s202.

30. Misch CE. The implant quality scale: A clinical assessment of the health–disease continuum. Oral Health 1998;88:15–25.


全部评论(0)


暂无评论

请选择购买类型
已成功加入购物车
E-Mail:
请输入邮箱