世界牙科技术
0
首页 > 网上书店 > 2022年10月第十期口腔综合版
日期:2022/09/21
前往购买本期杂志,或者关注微信公众号:
idpc1997
上一篇:无 下一篇:无
下颌应用7 mm 短种植体的1 年期前瞻性研究:比较不同植入方式、不同植入深度或不同种植体冠根比条件下的临床预后

前往购买本期杂志,或者关注微信公众号:
idpc1997
上一篇:无 下一篇:无

参考文献

 1. Misch CE, Suzuki J, Misch-Dietsh FD, et al. A positive correlation between occlusal trauma and peri-implant bone loss-literature support.Implant Dent. 2005;14:108–116.
2. Malo´ P, de AraujoNobre M, Rangert B. Short implants placed one stage in maxillae and mandibles: a retrospective clinical study with 1 to 9 years of follow-up. Clin Implant Dent Relat Res. 2007;9:15–21.
3. Romeo E, Ghisolf M, Rozza R, Chapasco M, Lops D. Short (8-mm) dental implants in the rehabilitation of partial and complete edentulism: a 3 to 14 year longitudinal study. Int J Prosthodont. 2006;19:586–592.
4. Stellingsma K, Raghoebar GM, Visser A, Vissink A, Meijer HJ. The extremely resorbed mandible, 10-year results of a randomized controlled trial on 3 treatment strategies. Clin Oral Implants Res. 2014;25:926–932.
5. Srinivasan M, Vazquez L, Rieder P, Moraguez O, Bernard JP, Belser UC. Efficacy and predictability of short dental implants (,8 mm): a critical appraisal of the recent literature. Int J Oral Maxillofac Implants. 2012;27: 1429–1437.
6. Rocci A, Martignoni M, Gottlow J. Immediate loading of Branemark system TiUnite and machined-surface implants in the posterior mandible: arandomized open-ended clinical trial. Clin Implant Dent Relat Res. 2003; 5(suppl 1):57–63.
7. Glauser R, Lundgren AK, Gottlow J, et al. Immediate occlusal loading of BranemarkTiUnite implants placed predominantly in soft bone: 1- year results of a prospective clinical study. Clin Implant Dent Relat Res. 2003; 5(suppl 1):47–56.
8. Sun HL, Huang C, Wu YR, Shi B. Failure rates of short (,10 mm) dental implants and factors influencing their failure: a systematic review. Int J Oral Maxillofac Implants. 2011;26:816–825.
9. Gentile MA, Chuang SK, Dodson TB. Survival estimates and risk factors for failure with 6 3 5.7 mm implants. Int J Oral Maxillofac Implants. 2005;20:930–937.
10. Sun HL, Huang C, Wu YR, Shi B. Failure rates of short (,10 mm) dental implants and factors influencing their failure: a systematic review. Int J Oral Maxillofac Implants. 2011;26:816–825.
11. Albreksson T, Zarb GA, Worthington P, Erickson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. J Oral Maxillofac Implants. 1986;1:11–25.
12. Lo¨ e H. The gingival index, the plaque index and the retention index systems. J Periodontol. 1967;38(6 suppl):610–616.
13. Lang NP, Loe H. The relationship between the width of keratinized gingiva and gingival health. J Periodontol. 1972;43:623–627.
14. Herrmann I, Lekholm U, Holm S, Kultje C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants. 2005;19:387–392.
15. Weng D, Jacobson Z, Tarnow D, et al. A prospective multicenter clinical trial of 3i machined-surfaced implants: results after 6 years of follow up. Int J Oral Maxillofac Implants. 2003;18:417–423.
16. Telleman G, Raghoebar GM, Vissink A, et al. A systematic review of the prognosis of short (,10mm) dental implants placed in the partially edentulous patient. J Clin Periodontol. 2011;38:667–676.
17. Rangert BR, Sullivan RM, Jemt TM. Load factor control for implants in the posterior partially edentulous segment. Int J Oral Maxillofac Implants. 1997;12:360–370.
18. Blanes RJ, Bernard JP, Blanes ZM, Belser UC. A 10-year prospective study of ITI dental implants placed in the posterior region. II: influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss. Clin Oral Implants Res. 2007;18:707–714.
19. Rokni S, Todescan R, Watson P, Pharoach M, Adegbemeh AO,Deporter D. An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients. Int J Oral Maxillofac Implants. 2005;20:69–76.
20. Tawil G, Aboujaoude N, Tounan R. Influence of prosthetic parameters on the survival and complication rates of short implants. Int J Oral Maxillofac Implants. 2006;21:275–282.
21. Anitua E, Pinas L, Orive G. Retrospective study of short and extra short implants placed in posterior regions: influence of crown-to-implantratio on marginal bone loss. Clin Implant Dent Relat Res. 2015;17:102–110.
22. Sotto-Major BS, Senna PM, da Silva WJ, Rocha EP, Del Bel Cury AA. Influence of crown-to-implant ratio, retention system, restorative material, and occlusal loading on stress concentrations in single short implants. Int J Oral Maxillofac Implants. 2012;27:e13–e18.
23. Birdi H, Schulte J, Kovacs A, Weed M, Chuang SK. Crown-to-implantratios of short-length implants. J Oral Implantol. 2010;36:425–433.
24. Rokni S, Todescan R, Watson P, Pharoah M, Adegbembo AO, Deporter D. An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients. Int J Oral Maxillofac Implants. 2005;20:69–76.
25. Bidez MW, Misch CE. Force transfer in implant dentistry: basic concepts and principles. J Oral Implantol. 1992;18:264–274.
26. Misch CE, Steigenga J, Barboza E, Misch-Dietsh F, Cianciola LJ, Kazor C. Short dental implants in posterior partial edentulism: a multicenter retrospective 6-year case series study. J Periodontol. 2006;77:1340–1347.
27. Yilmaz B, Seidt JD, McGlumphy EA, Clelland NL. Comparison of strains for splinted and nonsplinted screw-retained prostheses on shortimplants. Int J Oral Maxillofac Implants. 2011;26:1176–1182.
28. Kim YK, Kim SG, Oh HK, et al. Evaluation of perimplant tissue in nonsubmerged dental implants: a multicenter retrospective study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;108:189–195.
29. Schulte J, Flores AM, Weed M. Crown-to-implant ratios of single tooth implant-supported restorations. J Prosthet Dent. 2007;98:1–5.

全部评论(0)


暂无评论

请选择购买类型
已成功加入购物车
E-Mail:
请输入邮箱